How wildfires spread beyond their front

Wildfire spotting: detached fires in the Camp Fire record

By Phil Springer, Editor · Published · Prepper Debunk

Wildfire spotting: detached fires in the Camp Fire record

At 7:20 a.m. on November 8, 2018, observers recorded five small fires on the slopes west of Concow Reservoir in California. Each was estimated at roughly 3 meters square. Five minutes later, spot fires were igniting in Concow and houses were beginning to burn. Wildfire spotting had turned one advancing emergency into separated locations of combustion. NIST's reconstruction of the Camp Fire preserves those observations with their times, locations, and source identifiers, rather than drawing only a single outer boundary around everything eventually burned.

The incident command chronology captures the same problem from another direction. At 7:44 a.m., the emergency communications center received a call reporting three spots on the Paradise side of the canyon near Drayer Drive and Pentz Road. Around 7:45, incident objectives described a proposed containment area. Before those objectives were announced over the radio, spot fires had already been reported outside it. These entries, reproduced in an April 29, 2021 presentation by NIST researchers Alexander Maranghides and Eric Link, place detached ignitions within the early sequence of the fire's spread.

The underlying NIST case study, published in February 2021, collected more than 2,200 observations about fire behavior and progression. Its findings described initial winds reaching 50 miles per hour and long-range spotting reaching 3.9 miles, or 6.3 kilometers, into the community. Concow, Paradise, and Magalia were affected. Wildfire spotting was one contributor within a fire shaped by several interacting factors, including the original ignition's position relative to the communities. The investigators identified multiple routes by which fire reached individual properties; the detached ignitions belonged to a larger reconstruction, rather than an explanation that every structure burned in the same way.

A contemporary NASA image release provides a different kind of record. Published on November 9, 2018, it used a natural-color image collected the previous day by the VIIRS instrument aboard Suomi NPP. Red points represented actively burning locations detected through thermal bands. Its accompanying caption reported strong winds and long-range spotting while the cause of the fire remained under investigation. The image registered heat from active burning; it did not photograph every traveling ember. The later NIST chronology supplied the detailed local sequence that a broad satellite view could not provide by itself.

The material involved in spotting is a firebrand: burning matter carried away from its source and capable of beginning another fire where it lands. A separate NIST experiment published in 2012 examined production at that source. Sayaka Suzuki, Samuel Manzello, Matthew Lage, and George Laing studied a full-scale structure burn. Researchers collected firebrands in water pans and measured their size and mass distributions, comparing the specimens with material from vegetation and earlier investigations. The experiment documented a burning building as a source of airborne burning fragments, extending the evidence beyond tree crowns and other vegetation.

That distinction changes the setting in which wildfire spotting occurs. A community reached by fire contains structures as well as plants, and the full-scale experiment measured material released by a structure itself. It investigated firebrand generation, not the distance each specimen would travel during a particular wildfire. The Camp Fire chronology, by contrast, recorded where new fires were observed during an actual incident. Material collected at a source and an ignition recorded downwind describe different stages of the process. Combining them does not establish that a particular Concow firebrand came from a particular building.

An independent study used the 2017 Northern Rockies fire season to examine spotting distance across multiple fire-days. Wesley Page, Natalie Wagenbrenner, Bret Butler, and David Blunck's analysis appeared online on October 29, 2018, and in the Canadian Journal of Forest Research's 2019 volume. They compared maximum observed spot-fire distances with geographically referenced information on wind, vegetation, terrain, fire size, growth, and perimeter shape. Their observations came from infrared hot-spot data that covered broad areas but were limited in time. The study therefore examined the maximum distances present in that observational record, rather than following every firebrand continuously from release to landing.

The researchers found a positive statistical relationship involving the interaction of wind speed and fire growth. They also reported negative relationships with perimeter shape, canopy height, and terrain steepness. They evaluated a theoretical model developed by Frank Albini in 1979 for single trees or groups of torching trees. This was a comparison between observed fires and a model with a specified source of burning material. The results placed spotting distance within changing fire and environmental conditions, rather than assigning one universal distance to every wind-carried ember.

The Concow chronology also follows growth after the detached fires began. At 7:20 a.m., engines approaching the northern flank encountered an established spot fire of approximately a quarter to half an acre on Rim Road. By 7:30, spot fires there had grown to several acres within 10 minutes, spreading uphill and consuming the draw. Wildfire spotting had created new sources of continuing combustion. By 7:50, the recorded fire in Concow was well established, multiple structures were burning, and fire was affecting evacuation. The scattered early ignitions had developed rapidly after their arrival.

The Question

Which wildfire-spread mechanism is called spotting?

Show the answer

The Answer

That is spotting: wind-carried firebrands can start fires ahead of the main front. Winds and convection columns carry hot embers and other burning material over barriers, where they can ignite dry fuel downwind.

Send this question to a friend

Read next

By clicking “Send me the real story” you agree to Prepper Debunk’s Terms of Use and Privacy Policy.